DESCRIPTION
BURGLAR ALARM SYSTEM

The burglar alarm system is armed automatically after the doors, hood, and tailgate are closed and locked.

The system is set off when any of these things occur :

A door is forced open.

The tailgate is opened without using the key.

The hood is opened.

When the system is set off, the alarm sounds and the hazard lamp flash for about 30 seconds or until the system is disarmed by unlocking the transmitter.

For the system to arm, the ignition switch must be off and the key removed. Then, the body control module must receive signals that the doors, hood, and tailgate are closed and locked. When everything is closed and locked, none of the control unit inputs are grounded.

The door switches, hood switch and tailgate switch are all close and lock the doors with the remote transmitter and then the system arms immediately.

If anything is opened after the system is armed, the body control module gets a ground signal from that switch, and the system is set off.

If one of the switches is misadjusted or there is a short in the system, the system will not arm. As long as the body control module continues to get a ground signal, it thinks the vehicle is not closed and locked and will not arm.

KEYLESS ENTRY SYSTEM

The burglar alarm system is integrated with the keyless entry system. The keyless entry system allows you to lock and unlock the vehicle with the remote transmitter. When you push the LOCK/UNLOCK button, all doors lock. When you push the LOCK/UNLOCK button again, all doors unlock.

The room lamp, if its switch is in the center position, will come on when you press the UNLOCK button. If you do not open a door, the light will go off in about 30 seconds, the doors will automatically relock, and the burglar alarm system will rearm. If you relock the doors with the remote transmitter within 30 seconds, the light will go off immediately.

You cannot lock or unlock the doors with the remote transmitter if the key is in the ignition switch.

The system will signal you when the doors lock and unlock by flashing the hazard lamp once when they lock, and twice when they unlock.

FUNCTION
ANTI-THEFT WARNING SYSTEM
1.

SECURITY LED CONTROL

(1)

If the KEY IN is ON or ACC is ON or IGN1 is ON or IGN2 is ON, the LED shall be OFF.

(2)

When entered into the ARM WAIT mode in the IGN KEY OUT state, control not only the FULL ON but also the BLINKING in the mode other than the ARM WAIT.

(3)

The BLINKING cycle is 2.3 seconds, and it is ON for 0.3 seconds and OFF for 2.0 seconds.

T1 : 0.3s, T2 : 2s

2.

DISARM

Condition 1

State

Description

Initial Condition

ALARM

Transition Condition

-

When 4DOOR or T/GATE is OPEN and TX(Transmitter) UNLOCK is input

-

After 30 seconds in the KEY IN ON and IGN1 ON and IGN2 ON states

-

When all doors are unlocked (LOCK FAIL) within 5 seconds after the TX(Transmitter) LOCK input

Operating

-

ENTRY INTO THE DISARM STATE

-

HORN, HAZARD, B/ALARM output shall be OFF

-

In the case of the TX UNLOCK input, the HAZARD LAMP signal is output with the cycle of the ON/OFF of 0.5 seconds two times.

Condition 2

State

Description

Initial Condition

In the DISARM state and any one of the IGN KEY OUT & 4DOOR and T/GATE are opened

Transition Condition

When entering TX UNLOCK

Operating

-

Maintain in the DISARM state

-

The HAZARD LAMP signal is output with the ON/OFF cycle of 0.5 seconds two times.

Condition 3

State

Description

Initial Condition

ARM WAIT state

Transition Condition

-

When any one of the 4DOOR, HOOD or T/GATE is opened.

-

When at least one or more doors are unlocked.

-

In case of KEY IN.

-

When the DRIVER KEY UNLOCK(T/GATE KEY UNLOCK) signal is input

Operating

-

ENTRY INTO THE DISARM STATE

Condition 4

State

Description

Initial Condition

AUTOLOCK TIMER1 state

Transition Condition

-

When any one of the 4DOOR, HOOD or T/GATE is opened.

-

In case of KEY IN.

-

LOCK FAIL after the LOCK attempt by the AUTO LOCK.

-

LOCK FAIL after the LOCK attempt by the TX LOCK.

-

LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK(T/GATE KEY LOCK).

Operating

-

ENTRY INTO THE DISARM STATE

Condition 5

State

Description

Initial Condition

AUTOLOCK TIMER2 state

Transition Condition

-

When any one of the 4DOOR, HOOD or T/GATE is opened.

-

In case of KEY IN.

-

LOCK FAIL after the LOCK attempt by the AUTO LOCK.

-

LOCK FAIL after the LOCK attempt by the TX LOCK.

-

LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK (In case of B_MECH_KEY=Enable)

Operating

-

ENTRY INTO THE DISARM STATE

Condition 6

State

Description

Initial Condition

ARM state

Transition Condition

-

IGN KEY ON

-

DRIVER KEY UNLOCK(T/GATE KEY UNLOCK) input.

Operating

-

ENTRY INTO THE DISARM STATE

Condition 7

State

Description

Initial Condition

REARM state

Transition Condition

-

After 30 seconds in the IGN KEY ON state.

-

LOCK FAIL after the LOCK attempt by the TX LOCK.

-

LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK.

-

When entering DRIVER KEY UNLOCK.

Operating

-

ENTRY INTO THE DISARM STATE

-

B/ALARM RELAY OFF

Condition 8

State

Description

Initial Condition

REARM state

Transition Condition

-

In case of TX UNLOCK INPUT in the state that any one of the 4DOOR or T/GATE is opened.

-

In case of KEY IN.

-

In case of the 4DOORor T/GATE or HOOD is closed and at least one door is unlocked.

Operating

-

ENTRY INTO THE DISARM STATE

-

In the case of the TX UNLOCK INPUT, the HAZARD LAMP signal is output two times with the ON/OFF cycle of 0.5 seconds.

3.

ARM

Condition 1

State

Description

Initial Condition

ARM state

Transition Condition

When entering TX LOCK

Operating

-

Keep the ARM state

-

The HAZARD LAMP signal is output for 1s once.

Condition 2

State

Description

Initial Condition

ARM WAIT state

Transition Condition

After the ARM WAIT TIMER completion

Operating

-

ENTRY INTO THE ARM state

4.

ALARM

Condition 1

State

Description

Initial Condition

ARM state

Transition Condition

In case of 4DOOR, T/GATE or HOOD is opened.

Operating

-

ENTRY INTO THE ALARM state

-

The B/ALARM RELAY outputs is ON, and then, inhibit the start.

-

Non-EC area: the Horn alarm shall be output three times with the cycle consisting of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the Hazard Lamp signal shall also be output as the Horn alarm.)

-

EC and The Middle EAST: the HORN alarm output shall be ON for 27s(±2s) once. (At this time, the Hazard Lamp signal output shall also be ON as the Horn alarm.)

Condition 2

State

Description

Initial Condition

REARM state

Transition Condition

In case of 4DOOR, T/GATE or HOOD is opened.

Operating

-

ENTRY INTO THE ALARM state

-

Non-EC area: the Horn alarm shall be output three times with the cycle consisting of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the Hazard Lamp signal shall also be output as the Horn alarm.)

-

EC and The Middle EAST: the HORN alarm output shall be ON for 27s(±2s) once. (At this time, the Hazard Lamp signal output shall also be ON as the Horn alarm.)

T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec,

T3 : 10 ± 1sec.

T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec.

5.

ARM WAIT

Condition 1

State

Description

Initial Condition

ARM WAIT state

Transition Condition

When entering TX LOCK

Operating

-

Keep ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

Condition 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT & 4DOOR, T/GATE and HOOD CLOSE state

Transition Condition

-

In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT.

-

In case of 4DOOR, T/GATE, HOOD OPEN>CLOSE with all doors locked.

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

Start the ARMWAIT TIMER

Condition 3

State

Description

Initial Condition

ALARM state & IGN KEY OUT & 4DOOR, T/GATE and HOOD CLOSE state

Transition Condition

-

In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the ARM WAIT state

-

OFF the HORN, B/ALARM output.

-

The HAZARD LAMP signal shall be output for 1s once

-

Start the ARMWAIT TIMER

Condition 4

State

Description

Initial Condition

AUTOLOCK TIMER1 state

Transition Condition

-

In case of LOCK SUCCESS after the LOCK attempt by the AUTOLOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

In case of LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

Start the ARMWAIT TIMER

Condition 5

State

Description

Initial Condition

PREARM state

Transition Condition

-

4DOOR, T/GATE and HOOD are closed and all doors are locked.

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

Start the ARMWAIT TIMER

Condition 6

State

Description

Initial Condition

REARM state

Transition Condition

-

LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the ARM WAIT state

-

The HAZARD LAMP signal shall be output for 1s once.

-

B/ALARM RLY OFF

-

Start the ARMWAIT TIMER

6.

REARM

Condition 1

State

Description

Initial Condition

ALARM state

Transition Condition

4DOOR, T/GATE and HOOD are closed and after the ALARM PATTERN completion

Operating

-

Entry into the REARM state

7.

AUTO-LOCK TIMER1

Condition 1

State

Description

Initial Condition

ARM state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 state

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START the AUTOLOCK TIMER1

Condition 2

State

Description

Initial Condition

REARM state

Transition Condition

-

AUTO-LOCK TIMER1 state.

-

TX UNLOCK INPUT.

Operating

-

keep the AUTO-LOCK TIMER1 state

-

CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.

-

CASE2: TX UNLOCK

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times

-

RESTART THE AUTOLOCK TIMER1

Condition 3

State

Description

Initial Condition

ARM WAIT state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 state

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER

Condition 4

State

Description

Initial Condition

The DISARM state and 4DOOR, T/GATE and HOOD are closed and IGN KEY OUT

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 STATE

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER1

Condition 5

State

Description

Initial Condition

ALARM state, and 4DOOR, T/GATE and HOOD CLOSE state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 STATE

-

B/ALARM RELAY OFF

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER1

Condition 6

State

Description

Initial Condition

REARM state

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER1 STATE

-

B/ALARM RELAY OFF

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER1

8.

AUTO-LOCK TIMER 2

Condition 1

State

Description

Initial Condition

AUTO-LOCK TIMER2 state

Transition Condition

-

AUTOLOCK TIMER2 COMPLETION.

-

TX UNLOCK INPUT.

Operating

-

keep the AUTO-LOCK TIMER2 state

-

CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.

-

CASE2: TX UNLOCK

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times

-

RESTART THE AUTOLOCK TIMER1

Condition 2

State

Description

Initial Condition

REARM state

Transition Condition

DISARM state AND 4DOOR & T/GATE CLOSE & HOOD OPEN AND IGN KEY OUT

Operating

-

Entry into the AUTO-LOCK TIMER2 STATE

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER2

Condition 3

State

Description

Initial Condition

ALARM STATE AND 4DOOR & T/GATE CLOSE & HOOD OPEN STATE

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER2 STATE

-

OFF the HORN, B/ALARM OUTPUT

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER2

Condition 4

State

Description

Initial Condition

PREARM START AND 4DOOR & T/GATE CLOSE & HOOD OPEN STATE

Transition Condition

TX UNLOCK INPUT

Operating

-

Entry into the AUTO-LOCK TIMER2 STATE

-

The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.

-

START THE AUTOLOCK TIMER2

9.

PREARM

Condition 1

State

Description

Initial Condition

AUTO-LOCK TIMER2 state

Transition Condition

-

LOCK SUCCESS after the LOCK attempt by the AUTO LOCK.

-

LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the PREARM state

Condition 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT

Transition Condition

-

LOCK SUCCESS after the LOCK ATTEMPT by the TX LOCK in the state that 4 DOOR or T/GATE or HOOD is opened.

-

LOCK SUCCESS after the LOCK ATTEMPT by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT in the state that 4 DOOR or T/GATE or HOOD is opened.

-

The DOOR is turned to the CLOSE state from the OPEN state in the state that all doors are locked. But, the HOOD is opened.

Operating

-

Entry into the PREARM state

Condition 3

State

Description

Initial Condition

ALARM state & IGN KEY OUT & 4DOOR or T/GATE or HOOD OPEN

Transition Condition

-

LOCK SUCCESS after the LOCK attempt by the TX LOCK.

-

LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (T/GATE KEY LOCK) INPUT.

Operating

-

Entry into the PREARM state

-

OFF the HORN, HAZARD, B/ALARM OUTPUT

10.

RESET

Condition 1

State

Description

Initial Condition

ALARM, REARM state

Transition Condition

Insert after the BATTERY is withdrawn

Operating

-

The B/ALARM RELAY shall be ON and the HORN ALARM shall be output three times again (EC SPEC ONCE).

Condition 2

State

Description

Initial Condition

ARM state

Transition Condition

Insert after the BATTERY is withdrawn

Operating

-

Keep the ARM state.

Яндекс.Метрика