INSPECTION
MEASURING RESISTANCE
1.

Disconnect the cruise control switch connector from the control switch.

2.

Measure resistance between terminals on the multifunctior switch when each function switch is ON (switch is depressed).

Function switch

Multifunction switch Terminal

Resistance

Cruise Main

5-6

3.9kΩ ± 1%

Cancel

6-7

0Ω ± 1%

Set/Coast

6-7

220Ω ± 1%

Resume/Accel

6-7

910Ω ± 1%

3.

If not within specification, replace switch.