Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found ?

YES

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure

NO

▶ Go to "Signal Circuit Inspection" procedure.

Signal Circuit Inspection

■ Check short to ground in harness

1.

IG "OFF" and disconnect HO2S(B2/S1) connector.

2.

IG "ON" and ENG "OFF"

3.

Measure voltage between signal terminal of HO2S(B2/S1) harness connector and chassis ground.

a.

Specification :

Approx. 3.5V - when pumping current is ON

Approx. 0.45V - when pumping current is OFF

note
To view Flash content, you need to install the appropriate browser extension
4.

Is the measured voltage within specification?

YES

▶ Go to "Component Inspection" procedure.

NO

▶ Repair short to ground in harness, and go to "Verification of Vehicle Repair" procedure.

Яндекс.Метрика