Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C∼130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 Ω (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ω (VFS)
- Surge voltage: 56 V (Except VFS)
Input Current(mA) | Control Pressure (No line pressure) | |||
Increasing Current | Decreasing Current | |||
MAX. (Kgf/㎠) [Kpa] | MIN. (Kgf/㎠) [Kpa] | △ (Kgf/㎠) [Kpa] | MIN. (Kgf/㎠) [Kpa] | |
100 | 6.52[639] | 5.87[575] | [64] | |
200 | 6.23[611] | 5.70[559] | [52] | 5.43[532] |
300 | 5.76[564] | 5.24[514] | [50] | 4.49[484] |
400 | 5.08[498] | 4.59[450] | [48] | 4.30[421] |
500 | 4.24[416] | 3.78[370] | [46] | 3.52[345] |
700 | 2.29[224] | 1.82[178] | [46] | 1.51[148] |
800 | 1.41[138] | 0.09[88] | [50] | 0.58[57] |
900 | 0.65[64] | 0.14[14] | [50] | 0[0] |
1,000 | 0.24[24] | 0[0] | [24] | |
1,100 | 0.24[24] | 0[0] | [24] |
*Test condition:
Ps : Supply Pressure (Ps=7.1 ± 0.3 KGf/㎠)
Pc : Control Pressure
Pex : Exhaust Pressure (Atmosphere pressure)
ATF : DIAMOND ATF SP-Ⅲ
ATF temperature : 30 ± 3°C (86°F)
- Coil resistance : 4.35 ± 35Ω
- Dither Frequency : 600 ± 20Hz
In case of VFS solenoid valve, the relation between Duty and oil pressure can't be expressed.