DESCRIPTION
Actuators

Solenoid Valve for Pressure Control

- Sensor type: Normal open 3-way

- Operating temperature : -30°C∼130°C(-22°F~266°F)

- Frequency:

LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))

DCC: 30.64Hz

- Internal resistance:

3.0 ± 0.5 Ω (LR, 2ND, UD, OD, TCC)

4.35 ± 0.5 Ω (VFS)

- Surge voltage: 56 V (Except VFS)

(VFS)
Location
VFS Control pressure

Input Current(mA)

Control Pressure (No line pressure)

Increasing Current

Decreasing Current

MAX. (Kgf/㎠) [Kpa]

MIN. (Kgf/㎠) [Kpa]

△ (Kgf/㎠) [Kpa]

MIN. (Kgf/㎠) [Kpa]

100

6.52[639]

5.87[575]

[64]

200

6.23[611]

5.70[559]

[52]

5.43[532]

300

5.76[564]

5.24[514]

[50]

4.49[484]

400

5.08[498]

4.59[450]

[48]

4.30[421]

500

4.24[416]

3.78[370]

[46]

3.52[345]

700

2.29[224]

1.82[178]

[46]

1.51[148]

800

1.41[138]

0.09[88]

[50]

0.58[57]

900

0.65[64]

0.14[14]

[50]

0[0]

1,000

0.24[24]

0[0]

[24]

1,100

0.24[24]

0[0]

[24]

*Test condition:

Ps : Supply Pressure (Ps=7.1 ± 0.3 KGf/㎠)

Pc : Control Pressure

Pex : Exhaust Pressure (Atmosphere pressure)

ATF : DIAMOND ATF SP-Ⅲ

ATF temperature : 30 ± 3°C (86°F)

- Coil resistance : 4.35 ± 35Ω

- Dither Frequency : 600 ± 20Hz

In case of VFS solenoid valve, the relation between Duty and oil pressure can't be expressed.

Яндекс.Метрика