INSPECTION
1.

Adjusting method for T/M control cable

(1)

Set room side lever and T/M side lever to "N" position.

(2)

Connect room side lever and shift cable.

(3)

Connect T/M side lever to cable in a following orders.

A.

Push cable lightly to "F" direction shown to eliminate FREE PLAY of cable.

B.

Tighten adjusting nut(C).

(4)

After adjusting according to (2)-(4). Check to be sure that this part operates surely at each range of T/M side corresponding to each position of room lever.