Component Location
General Description

Alternator output and power demand of all electrical loads and systems must be matched to each other as ideally as possible so that the entire system is reliable and trouble-free in operation. The ECM monitors alternator output deviation from the signal of the FR terminal of the alternator when the engine is running.

DTC Description

P0620 is set when alternator control circuit is open or short at IG "ON"

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Signal Monitoring

Control circuit is open or short

Poor connection or damaged harness

Enable Conditions

IG "ON"

Threshold value

Signal circuit is open or short

Diagnosis Time

1sec

MIL On Condition

OFF