Component Location
General Description

A/C pressure transducer consists of piezoelectric element and it detects A/C refrigerant pressure. Piezoelectric type is more advantageous to obtain linear data of pressure than existing switch type. Thus, optimum control of A/C compressor and fan is realized and improved fuel efficiency follows with it.

DTC Description

P0533 is set when the voltage above 4.87V - maximum voltage of A/C pressure transducer signal - is detected for more than 0.6 sec.. This code is due to open or short in signal or ground circuit of A/C pressure transducer.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

A/C pressure transducer circuit

A/C pressure transducer component

Enable Conditions

IG key ON

Threshold Value

When output signal is above the maximum value (above 4870mV).

Diagnostic Time

0.6 sec.

Fail Safe

Fuel cut

NO

40000hpa(40bar) at fail safe mode.

EGR Off

NO

Fuel Limit

NO

MIL

OFF

Specification
Diagnostic Circuit Diagram
note
To view Flash content, you need to install the appropriate browser extension
Signal Waveform & Data

Fig.1) Waveform of A/C pressure transducer in accordance with A/C operation. (A/C compressor operation)

☞ Output signal(voltage) changes in accordance with the amount of refrigerant and the change of weather occurs.

Check if normal pressure change in accordance with A/C compressor operation at normal pressure range shown in "Specification".