The Throttle Control Actuator is mounted on throttle body of diesel engine and controls throttle valve according to PWM (Pulse With Modulation) signal from ECM.
It consists of;
1. a DC motor which actuates the throttle valve,
2. a 2-step gear (transmission ratio = 1:40) which is located in between the DC motor and the throttle valve and increases torque of the DC motor,
3. a position sensor which is a hall-effect sensor and detects status of the throttle valve,
4. an electric control unit which is a micro-controller and drives the DC motor by the PWM (Pulse With Modulation) signal from the ECM,
5. and a reset spring which resets the de-energized throttle valve to its open position.
Its function is described below:
1. Anti-judder function: When engine is shut off, the ECM can prevent intake air from entering to intake manifold by fully closing the throttle valve for 1.5 seconds (95% < Duty <97%) to reduce engine vibration.
2. Intake air control for EGR: When exhaust gas pressure is equal to or lower than intake air pressure (for example, when low engine speed), the exhaust gas would not enter to the intake manifold. At this time, the ECM partially closes the throttle valve (5% < Duty < 94%) to reduce the intake air quantity. The intake air pressure thus is lower than the exhaust gas pressure.
3. Exhaust gas temperature control for CPF regeneration: When the Catalyzed Particulate Filter (CPF) is need to regenerate, the ECM partially closes the throttle valve (5% < Duty < 94%) to reduce the intake air quantity. At this time, the air-fuel ratio would become rich and the exhaust gas temperature would be high enough to burn the soot inside the CPF.
P2113 is set when 1)throttle valve actuator error or 2)open or short of Feedback line is detected for more than 5 sec. This code is due to throttle control actuator stuck, open or short in feed back signal circuit.
Item | Detecting Condition | Possible Cause | |
DTC Strategy | ● Voltage monitoring | ● TCA circuit ● TCA component | |
Enable Conditions | ● IG KEY "ON" | ||
Threshold Value | ● Short to GND, Wiring open | ||
Diagnostic Time | ● 5 sec. | ||
Fail Safe | Fuel Cut | NO | |
EGR Off | NO | ||
Fuel Limit | NO | ||
Check Lamp | NO |
Throttle control actuator fully opened | Throttle control actuator fully closed | Throttle control actuator operating Hz |
5% | 95% | 250±7.5 Hz |