Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the center lower side cover.

[LHD]
[RHD]
3.

Disconnect the evaporator sensor connector (A).

4.

Remove the evaporator temperature sensor(B), by pulling it after rorating 90° in a counterclockwise direction.

[LHD]
[RHD]
caution

Take care that evaporator core pins are not bent.

5.

Installation is the reverse order of removal.