Removal
1.

Disconnect the ventilation hose quick-connector (A) and the vapor hose quick-connector (B).

2.

Disconnect the vapor hose quick-connector (A).

3.

Remove the protector installation bolts (A) and nut (B), and then remove the canister.

Inspection
1.

Check for the following items visually.

- Cracks or leakage of the canister

- Loose connection, distortion, or damage of the vapor hose/tube

A: Canister ↔ Atmosphere

B: Canister ↔ Fuel Tank

C: Canister ↔ Intake Manifold

Installation

Installation is the reverse of removal.

Canister protector installation bolt/nut:

3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)