Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the PCSV connector.

3.

Measure resistance between the PCSV terminals 1 and 2.

4.

Check that the resistance is within the specification.

Specification: Refer to “Specification”

Removal
1.

Turn the ignition switch OFF and disconnect the battery negative (-) cable.

2.

Disconnect the purge control solenoid valve connector (A).

3.

Disconnect the vapor hoses (B) from the purge control solenoid valve.

4.

Remove the bracket installation bolt (C), and then remove the valve from the surge tank.

Installation
caution

Install the component with the specified torques.

Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.

caution

Be careful of foreign material not to flow into the valve.

1.

Installation is reverse of removal.

Purge control solenoid valve bracket installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

Яндекс.Метрика