Component Location
General Description

Rail pressure regulator valve(RPRV) is installed in common rail and controls common rail pressure fast as regulating returning quantity of fuel which is delivered to common rail when fast rise of rail pressure is required like the moment of turning engine ON or when fast relief of pressure is required like at the point of deceleration. The lower rail pressure regulator valve current is, the more fuel is supplied to common rail. Thus it leads rail pressure to be high. On the contrary, the higher rail pressure regulator valve current is, the less fuel is supplied to common rail.

DTC Description

P0092 is set when excessive current in power circuit of PRV (integrated with common rail) is detected for more than 0.28 sec. This code is due to short to battery in power circuit or PRV internal short.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

PRV circuit

PRV

Enable Conditions

IG key ON

Threshold Value

Short to battery in PRV control circuit.

Diagnostic Time

280ms

Fail Safe

Fuel cut

YES

-

EGR Off

NO

Fuel Limit

NO

Check Lamp

ON

Specification

Rail pressure regulator valve resistance

Operating frequancy

3.42 ~ 3.78Ω (20℃)

1000Hz(1KHz)

Diagnostic Circuit Diagram
note
To view Flash content, you need to install the appropriate browser extension
Signal Waveform & Data

Fig.1) The sensor signal waveform at acceleration and no load.