Set room side lever and T/M side lever to "N" position.
Connect room side lever and shift cable.
Connect T/M side lever to cable in a following orders.
Push cable (A) lightly to "F" direction shown to eliminate FREE PLAY of cable after mounting the nut (B) lightly.
Tighten adjusting nut (B).
Tightening torque:
7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)
After adjusting according to (2)-(4). Check to be sure that this part operates surely at each range of T/M side corresponding to each position of room lever.