Removal and Installation
1.

Disconnect the battery negative cable (A).

2.

Disconnect the starter cable (A) from the B terminal on the solenoid then disconnect the connector (B) from the S terminal.

Tighting torque :

1.9 ~ 2.8 N.m (18.6 ~ 27.4 kgf.m, 13.7 ~ 20.3 lb-ft)

3.

Remove the bolts holding the starter, then remove the starter.

Tighting torque :

49.0 ~ 63.7 N.m (5.0 ~ 6.5 kgf.m, 36.2 ~ 47.0 lb-ft)

4.

Installation is the reverse of removal.