Inspection
1.

Ignition "OFF"

2.

Disconnect the connector of mode control actuator.

3.

Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3 and grounding terminal 4.

4.

Verify that the mode control actuator operates to the vent mode when connecting in the reverse.

5.

Check the voltage between terminals 5 and 7.

Door position

Voltage (5-7)

Error detecting

Vent

0.3 ± 0.15V

Low voltage :

0.1V or less

Defrost

4.7 ± 0.15V

High voltage :

4.9V or more

It will feedback current position of actuator to controls.

6.

If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation.

7.

If the problem is corrected, replace the mode control actuator.

Яндекс.Метрика