Connect scan tool with 'DATA LINK CONNECTOR' (DLC).
Warm engine up to normal operating temperature.
Turn all the electrical devices including air conditioner OFF.
Monitor "A/C ON SIGNAL SWITCH" and "A/C PRESSURE SENSOR" parameter on the scan tool.
Reference value :
"A/C ON SIGNAL SWITCH" is "OFF" : "A/C PRESSURE SENSOR" is 1200mV~1800mV
"A/C ON SIGNAL SWITCH" is "ON" : Higher than A/C "OFF" pressure by more than 500mV
Fig.1) Data at idle and A/C "OFF".
Fig.2) Data at idle and A/C "ON". A/C pressure transducer output voltage increases as A/C compressor operates.
☞ A/C pressure transducer voltage varies too much, therefore do not concern too much about the figure instead, check the rising tendency of A/C pressure transducer.