Inspection
1.

Ignition "ON"

2.

Using the scan tool.

3.

Check the output voltage of AQS between terminals 2 and 3.

Specification

Condition

Output signal

Fresh/recirculation

Normal condition

4 ~ 5V

Fresh

Hazardous gas detection

0 ~ 1V

Recirculation

4.

AQS diagnosis and fail safe

Detect the open of signal for 7 seconds without choosing the AQS switch when IG on.

If 2.5V or more is detected for 3.5 seconds or more among 7 seconds, be judged the open of AQS signal.

Operate as below fail safe function, while choosing AQS.

Fail safe: Release the AQS (AQS cannot be selected), Fresh/recirculation maintains previous situation of AQS selection.

note

When IG is turned ON, AQS heats for 34±5 seconds, it will output below 1.0 voltage during this time.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the front bumper.

(Refer to BD group - "Front Bumper")

3.

Remove the AQS (A) after loosening the mounting screws.

4.

Installation is the reverse order of removal.