Component Inspection
■ Check ECTS resistance
1.

IG key OFF.

2.

Disconnect ECTS connector.

3.

Check resistance between 'Signal' terminal and 'Ground' terminal of 'ENGINE COOLANT TEMPERATURE SENSOR' connector. (ECTS component side)

Specification

Temp.

Resistance

- 40℃

48.14㏀

- 20℃

14013 ~ 16.83㏀

Temp.

Resistance

0℃

5.79㏀

20℃

2.31 ~ 2.59㏀

Temp.

Resistance

40℃

1.15㏀

60℃

0.59㏀

Temp.

Resistance

80℃

0.32㏀

100℃

0.19㏀

Temp.

Resistance

110℃

0.145 ~ 0.149㏀

120℃

0.116㏀

note
To view Flash content, you need to install the appropriate browser extension
4.

Is the measured value within specification?

▶ Go to "Verification of Vehicle Repair" procedure.

▶ Replaces ECTS, and go to "Verification of Vehicle Repair" procedure.