Mode
Configuration State
All sensors should be in the High Line (Auto) state.
In High Line (Auto) configuration, sensor transmissions occur every 1 minute (nominal) and pressure is measured every 4 seconds.
Normal Delayed Auto State
This is High Line specific and is used for all HMC/KMC High Line applications.
In this state, the sensor will transmit for approx. 12 minutes before automatically entering storage state.
Storage Auto State
This state is a Low quiescent current state.
In this state;
Ignition off. The sensor does not measure pressure / temperature / battery level. The sensor will not transmit, unless requested to do so by the initiate command. |
Alert State
The sensor automatically enters this state if the measured temperature exceeds 110°C and over temperature shutdown is likely.
In this state, pressure is measured every 4 seconds and RF data transmitted every 4 seconds.
The state lasts for 1 minute if it is pressure triggered.