DTC Description

P0117 is set when the voltage below 200mV - minimum output voltage of ECTS - is detected for more than 2.0 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

ECTS circuit

ECTS component

Enable Conditions

IG KEY "ON"

Threshold Value

Output signal below the minimum value.(below 200mV)

Diagnostic Time

2.0 sec.

Fail Safe

Fuel cut

NO

During engine operation : temperature is fixed at 80℃

at cranking : temperature is fixed at -10℃

EGR Off

YES

Fuel Limit

NO

Check Lamp

NO

Яндекс.Метрика