P0116 is set when the signal of ECTS is not changed under Engine running condition.
Item | Detecting Condition | Possible Cause | ||
DTC Strategy |
•
Voltage monitoring |
•
ECTS circuit
•
ECTS component | ||
Enable Conditions |
•
IG KEY "ON" | |||
Threshold Value |
•
The signal of ECTS is not changed under Engine running condition. | |||
Diagnostic Time |
•
600msec. | |||
Fail Safe | Fuel cut | NO |
•
During engine operation : temperature is fixed at 90℃ | |
EGR Off | NO | |||
Fuel Limit | YES | |||
MIL | NO |