Item | Detecting Condition | Possible Cause | ||
DTC Strategy |
•
Voltage monitoring |
•
RPS circuit
•
RPS component | ||
Enable Conditions |
•
Engine running | |||
Threshold Value |
•
Output value form AC convertor is lower than -112bar | |||
Diagnostic Time |
•
300ms | |||
Fail Safe | Fuel cut | NO |
•
Rail press. Sensor value fixed at 330bar | |
EGR Off | NO | |||
Fuel Limit | YES | |||
Check Lamp | YES |
P0192 is set when RPS output value form AC convertor is lower than -112barfor more than 0.3 sec.. This code is due to the open in power circuit or the short to ground in signal circuit.