DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

RPS circuit

RPS component

Enable Conditions

Engine running

Threshold Value

Output value form AC convertor is lower than -112bar

Diagnostic Time

300ms

Fail Safe

Fuel cut

NO

Rail press. Sensor value fixed at 330bar

EGR Off

NO

Fuel Limit

YES

Check Lamp

YES

DTC Description

P0192 is set when RPS output value form AC convertor is lower than -112barfor more than 0.3 sec.. This code is due to the open in power circuit or the short to ground in signal circuit.