DTC Description

The SRSCM sets DTC B133400 if there is any error in communication between PFIS and SRSCM

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Check Data

1.

Short to power in harness.

2.

Short to ground in harness.

3.

Poor connection of connected part(open).

4.

Faulty PFIS.

5.

SRSCM's connector and circuit

Enable Conditions

•

Ignition "ON"

Threshold Value

•

PFIS no acceleration data and line voltage is ok (between 3V and 11V)

Diagnostic

Time

Qualification

•

More than 5 ms

De-

Qualification

•

More than 10 ms