DTC Description

The SRSCM sets DTC B147500 if there is a short to ground in DCAB harness.

*In this case, SRSCM checks if there's any fault in circuit by sending current for a while.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Check Voltage

1.

Short to ground in DCAB harness.

2.

Poor connection of connected part.

3.

Poor connection between shorting bar and release pin.

4.

Faulty DCAB.

5.

Check SRSCM.

Enable Conditions

•

Ignition "ON"

Threshold Value

•

DCAB squib line voltage is less than 0.9V(When Batt 7.4~18.7V)

Diagnostic

Time

Qualification

•

More than 4 sec

De-

Qualification

•

More than 8 sec