DTC Description

The SRSCM sets DTC B147600 if there is a short to power in DCAB harness.

*In this case, SRSCM checks if there's any fault in circuit by sending current for a while.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Check Voltage

1.

Short to power in DCAB harness.

2.

Poor connection of connected part.

3.

Poor connection between shorting bar and release pin.

4.

Faulty DCAB.

5.

Check SRSCM.

Enable Conditions

•

Ignition "ON"

Threshold Value

•

DCAB squib line voltage is greater than 2.9V( When Batt 7.4~18.7V)

Diagnostic

Time

Qualification

•

More than 4 sec

De-

Qualification

•

More than 8 sec

Яндекс.Метрика