DTC Description

The Air conditioner Control Module sets DTC B1281 when the auto defogger sensor signal has been detected short to ground circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Monitoring the Voltage

1.

Poor connection in wiring harness

2.

Short to ground in signal Circuit

3.

Short to ground in power Circuit

4.

Open in signal circuit

5.

Open in power circuit

6.

Open in ground circuit

7.

Auto defogger sensor(Humidity sensor)

8.

Faulty A/C control Module

Enable Conditions

IG KEY ON

Threshold value

Auto defogger sensor signal circuit is short to ground for 2seconds

Failsafe

Air Conditioner Control Module Controls humidity as 0%