Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor connection. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration,or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to next procedure.

Signal Circuit Inspection
■ Check short to battery in harness
1.

Ignition "OFF"

2.

Disconnect auto defogger actuator and A/C control Module main harness connector.

3.

Ignition "ON"

4.

Measure voltage between signal terminal of auto defogger actuator harness connector and chassis ground.

Specification : 0V

5.

Is the measured voltage within specification?

▶ Go to Next procedure.

▶ Check for short to battery in harness.

▶ Repair as necessary and then go to "Verification of Vehicle Repair" procedure.