DTC Description

The Air conditioner Control Module sets DTC B1250 when feedback signal of mode actuator has been detected over 4.9V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Monitoring the Voltage

1.

Short to battery in signal(Feedback) circuit

2.

Open in ground circuit

3.

Faulty mode actuator

4.

Faulty A/C control Module

Enable Conditions

•

IG KEY ON

Threshold value

•

Feedback signal of mode actuator has been detected over 4.9V for 0.3 seconds

Failsafe

•

If the Mode actuator is placed at Vent mode right before fail detection, Actuator is operated and fixed to Vent Mode Postion

•

In case of the others, Actuator is moved to DEF mode position