EPS CM controls EPS solenoid current accurately according to vehicle speed. EPS CM monitors that operating voltage supplied as IG S/W is too high or too low on "power supply terminal". If excessive high voltage or low voltage is detected, EPS CM stops current supply to solenoid to prevent unexpected operation or damage.