DTC Description

P401 is set when ECM detects that duty amount of EEGR actuator contol valve, ENG speed or amount of EGR is exceeded to minimum set point last to more than 15sec. In this case, check that stuck of EEGR actuator, air leakage of intake line.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal monitoring

EGR actuator stuck

EGR actuator component

Air leakage of intake line

Enable Conditions

Engine running

Threshold Value

Real value - Target value > upper specified air amout value

Diagnostic Time

15 sec.

Fail Safe

Fuel cut

NO

EGR Off

YES

Fuel Limit

NO

MIL

YES