DTC Description

P0406 is set when EGR position feedback signal(real value) is above than target value for 2.5 sec.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal monitoring

•

EGR actuator stuck

•

EGR actuator component

•

EGR actuator control circuit

Enable Conditions

•

Engine running

Threshold Value

•

When EGR position feedback signal(real value) is above than target value.

Diagnostic Time

•

2.5 sec.

Fail Safe

Fuel cut

NO

EGR Off

YES

Fuel Limit

NO

MIL

ON