Disconnect the battery negative (-) cable.
Disconnect the battery sensor connector (A).
Remove the battery negative (-) cable after removing the bolt (B).
Install in the reverse order of removal.
Battery sensor cable installation bolt :
21.6 ~ 32.4 N.m (2.2 ~ 3.3 kgf.m, 15.9 ~23.9 lb-ft)
Battery (-) terminal l tightening nut :
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)