Bleeding Air in Low Pressure Fuel Circuit
1.

Press the priming pump (A) about 50 times.

2.

Open the air bleeding hall after removing the bolt (B) for bleeding using a screwdriver.

3.

After install the screw, press the priming pump (A) again about 15 times.

4.

Open the air bleeding hall after removing the bolt (B) for bleeding using a screwdriver.

5.

After install the screw, press the priming pump (A) again about 5 times.

note
●

The number of pressing the priming pump is an estimated number.

If you work this procedure actually, you should press the priming pump until it gets stiff.

●

After removing or replacing the part below, bleed air in low pressure fuel circuit.

- Fuel Tank

- Fuel Sender

- Fuel Filter

- High Pressure Fuel Pump

- Low Pressure Fuel Lines

caution
●

If you try bleeding air just once, air is not bleeded perfectly.You should try bleeding air over 2 times.

Яндекс.Метрика