Disconnect the negative (-) battery terminal.
Remove the crash pad side cover.
Remove the crash pad lower panel (A).
(Refer to Body - "Crash Pad Lower Panel")
Connect the battery voltage (13.5V) between terminals 3 and 4.
Measure the voltage between terminals 4 and 5 at each position.
Switch Position | Rotation | Voltage (V) (±5V) |
0 | 0° | 11.4 |
1 | 18° | 10.7 |
2 | 36° | 9.9 |
3 | 54° | 9.4 |
4 | 72° | 8.8 |
5 | 90° | 8.3 |
6 | 108° | 7.7 |