AIR TEMPERATURE SENSOR (ATS)

SENSOR INSPECTION

1.

Inspect the resistance of sensor using a multi-tester.

2.

Measure teh resistance between ATS and terminal.

CONDITION

TEMPERATURE (°C)

RESISTANCE (kΩ)

Ignition ON

-40

-30

-20

-10

0

+10

+20

+30

+40

+50

+60

+70

+80

+90

+100

+110

+120

+130

39.260

22.260

13.850

8.609

5.499

3.604

2.420

1.662

1.166

0.835

0.609

0.452

0.340

0.261

0.202

0.159

0.127

0.102

3.

If resistance value is out of standard, replace the intake air temperature sensor is integrated in AFS.

WIRING HARNESS INSPECTION

Refer to P0112, P0113 DTC inspection procedures.