DESCRIPTION
SWITCH OPERATION AND FEATURES

Switch

Feature

Switch selection

Function

Temp switch

Push DOWN button at set temperature of 25°C while operating

Select at intervals of 0.5°C from 17°C to 25°C

Indication screen

Push DOWN button at set temperature of 25°C while operating

Selecte at intervals 0.5°C from 17°C to 25°C

Indication screen

AUTO switch

Push AUTO switch under system OFF or manual opeation

Control automatically all outlet by input value of each sensor

Indication screen

Push AUTO switch under automatic operation

Unchanged

Indication screen

MODE switch

Push MODE switch while operating

Indicate the followings repeatedly wheneverpushing the switch under set condition. Vent → By level → Floor → Mix

Indication screen

Push MODE switch under system OFF

Release AUTO mode and keep system OFF

OFF switch

Push OFF switch while operating

System OFF (keep TEMP and MODE intake in original condition and turn OFF blower and compressor

Indication screen

A/C switch

When air conditioner is OFF, push A/C switch under system OFF or operating

Turn ON air conditioner outlet

Push A/C switch under air conditioner ON

Turn OFF air conditioner outlet

Air intake switch

When system is OFF, push intake switch under air outlet condition

Keep system OFF na intake door turn to air intake mode

When system OFF, push intake switch under air intake condition

Keep ststem OFF and intake door turn to air outlet mode

Push intake switch under air outlet when operating

Air intake mode

When operating, push intake switch under air intake condition

Air outlet mode

Air outlet mode indicator condition

Air intake mode indicator condition

DEF switch

Push DEF switch when operating DEF mode or system OFF

Mode door : to DEF mode

A/C : ON

Intake : Outlet mode

Others : Condition before OFF

Indicator and indication screen

Push DEF switch when operating DEF mode

Return to the condition before DEF mode

AQS switch

Push AQS switch under AQS stopped

Control intake door by AQS signal while turning on AQS indicator

Push AQS switch when operating AQS

Return to the state before selecting AQS while turning off AQS indicator

Push OFF switch when operating

Turn off indication screen and AQS indicator, and intake door fixes to air intake mode

Able to select AQS, air intake, and air outlet when system OFF

Indicator condition while operating AQS

Indicator condition under AQS stopped

Blower switch

Push blower switch ▼ while operating

Voltage between both edges of blower motor goes down to 3.8V

Indication screen

Push blower switch ▲ while operating

Votage between both edges of blower motor goes up to Max high

Indication screen

Push blower switch under system OFF

Operate with 3.8V between both edges of blower motor

Indication screen

CONTROL SPECIFICATION

Control item

Control features

Remarks

Required discharge temperature

Required temperature determined by the set temperature and the inputted sensor value.

Auto control

Required discharge temperature is determined by the set temperature and the inputted sensor value. The feature will use the required discharge temperature to perform the auto control of temp. actuator, mode actuator, intake actuator, blower motor and compressor, and maintain the set temperature stably.

IN-CAR temperature correction

Upon detecting rapid changes of temperature from the INCAR sensor, it will gradually correct the incar temperature value.

-

1°C UP/4sec delay

-

1°C DOWN/4sec delay

AMB temperature correction

Upon detecting rapid changes of temperature from the AMB sensor, it will gradually correct the ambient temperature value.

Logic of the correction speed sensor

Photo correction

Upon detecting rapid changes of photo intensity from the PHOTO sensor, it will gradually correct the photo intensity value.

-

350 → 1000(W/m²)/1min delay

-

350 → 1000(W/m²)/5min delay

TEMP door control

It does the automatic control to maintain the optimum TEMP door opening (0%-100%). It will be computed by the temperature set and the input signal from each sensor.

The set temperature range 17°C→32°C, 0.5°C step (62°F→90°F, 1°F step)

Blower speed

Automatic control of the blower speed. The target value will be computed by the set temperature and the input signal from each sensor. (8 levels may be selected in case of manual selection.)

-

Auto mode blower low voltage (Manual low voltage: 3.8)

-

Auto mode heater blower HI speed: 10.6V

Electro-motive mode control

During auto control, it will raise the permitted voltage of blower motor gradually in order to improve comfortability.

12 seconds for shifting LO→MAX HI

Photo compensation

During auto control, it will compensate the blower level and the discharge temperature according to the photo intensity detected from the PHOTO sensor. PHOTO compensation will begin after 5 seconds when ignition on.

Mode door control

Automatic control of air discharge based on the required discharge temperature. It will be computed by the temperature setting and the input signal from each sensor.

(VENT → B/L → FLOOR → VENT)

In case of manual selection

(VENT → B/L → FLOOR → MIX → VENT)

-

At OFF, MODE door will fix the current condition.

-

At OFF in manual mode, MODE door will maintain the manual control condition.

MIX mode control (in auto control)

If the ambient temperature is -13°C or less in AUTO mode, discharge mode will be controlled at MIX. (When front window glass is defogged.)

Entering MIX mode, A/C will operate.

INTAKE door control

Auto control of intake mode based on the required discharge temperature that will be computed by the temperature setting and the input signal from each sensor.

-

Shift to REC when selecting REC button at FRE condition (LED on).

-

Shift to FRE when selecting FRE button at REC condition (LED off).

INTAKE control at OFF

The intake door will fix to the FRE. position when switching the system off.

-

FRE./REC. manual selection will be enabled at OFF

-

REC indicator will come out at OFF.

Compressor auto control

Control automatically the compressor on/off state corresponding to the set temperature and the input signal from each sensor.

-

When selection the AUTO SW, the compressor is controlled to ON/OFF.

-

When selection the DEF SW, the compressor is controlled to "ON".

Compressor clutch on/off control based on refrigerant temperature

If EVAP sensor temperature is below than 0.5°C, the compressor will be ON and the temperature is 3°C, or higher, with the compressor OFF.

MAX HOT

When selecting the set temperature HI at AUTO mode, MAX HOT will be performed. It will prevail over MIX mode control.

-

TEMP door: MAX HOT

-

MODE door: FLOOR mode

-

INTAKE door: FRE mode

-

Compressor: OFF

-

Blower speed: AUTO HI(10.6V)

MAX COOL

When selecting the set temperature LO at AUTO mode, MAX COOL will be performed.

-

TEMP door: MAX COOL

-

MODE door: FLOOR mode

-

INTAKE door: REC mode

-

Compressor: ON

-

Blower speed: MAX HI

Electromotive heating control

If the ambient temperature is 5°C or more and the in-car temperature is 10°C or less than the ambient temperature at B/L or FLOOR in AUTO mode, it will effect the electromotive heating control to prevent outside cold air from flowing toward the feet of passengers.

-

Blower speed: Controlled at AUTO LOW (4.5V)

As the coolant temperature rises, the MODE door will shift to DEF → AUTO.

Operation release

In-car temp. > ambient +10°C

Max cool

In pressing MODE switch.

In pressing DEF switch.

MODE: Manual selection is enabled.

INTAKE door: At AUTO control or at manual selection mode.

Blower speed: Manual selection is enabled (No re-entry).

Electromotive cooling control

In order to prevent hot air from the VENT or B/L in AUTO mode (A/C on mode blower auto ), the blower speed will be operated at LOW for approx. 9 seconds before entering the AUTO control if the EVAP sensor detection is temperature 30°C or higher.

MAX HOT

If the above condition is satisfied, electromotive cooling control will operate at any time.

Air Quality System (AQS)

The AQS system will detect the hazardous elements and odors contained in the air. If the harmful element concentration is higher than standard, the system will output a LOW signal (1.0V or less) to the FATC.

-

When the initial battery connection and ignition is ON, it will operate at AUTO mode. (AQS will not operate.)

If the concentration is within the standard value, the system will output a HI signal (4V) the FATC.

-

When IGN 2 ON, the AQS assembly will be preheated for 34.5±5seconds.

Corresponding to the signal from the AQS, it will control the INTAKE door as follows to prevent the inflow of harmful gas in FATC:

-

IGN2 ON: It will check circuit break on the AQS assembly's signal line for approx. 7 seconds during the preheating, irrespective to the AQS switch condition.

Condition

INTAKE door position

-

When AQS is selected prior to IGN2 OFF and IGN2 is turned OFF → ON: AQS indicator will come on, and the system will operate at AQS mode. (Store the previous condition before IGN 2 OFF)

LOW

REC

HI

FRE

Initialization Upon battery-on

When supplying the initial power, it will operate in the initial condition.

-

When the initial ignition ON after battery connection, the system will operate at the set temperature 25°C and at AUTO mode.

Memory

When removing ignition key, it will store FATC'S operating condition.

-

When IGN ON after IGN OFF during FATC operation, the system will operate at the previous before the ignition off.