The purpose of the Inspection is to analyze the cause of hesitation through ignition coil inspection.
IG "OFF"
Measure primary resistance after removing ignition coil connectors. (Primary resistance is measured between (+) terminals and (-) terminals.)
Measure secondary resistance after removing spark plug cables. (Secondary resistance is measured between center terminals and center terminals.)
Specification of Ignition Coil Resistance
Primary Coil : 0.96Ω ± 10% , Secondary Coil : 12.5㏀ ± 15%
Are the primary and secondary resistance of the ignition coil normal?
YES
Ignition coil is OK.
NO
Replace the ignition coil.