Description

If the potential (votage drop) of the terminal "B" or ground harness is over threshold value, Impossible cranking could occur. Check the starter by measuring the potential(Votage drop).

Diagnostic Procedure
Starter Inspection (Terminal "B" of the starter Inspection)
1.

IG "START"

2.

Measure the potential (Voltage drop) between terminal B of starter and battery (+) terminal.

caution

Probe(+) : Battery (+) terminal

Probe(-) : Terminal "B" of the starter

A.

Specification : Below 0.5V

3.

Is the potential (Voltage drop) within Specification?

YES

Go to "Starter Chassis ground Inspection" procedure.

NO

Replace harness between battery(+) terminal and terminal B of starter.

Starter Chassis ground Inspection
4.

IG "START"

5.

Measure potential (Voltage drop) between battery(-) terminal and chassis ground.

caution

Probe(+) : Battery (-) terminal

Probe(-) : Chassis ground

A.

Specification : Below 0.5V

6.

Is the potential (Voltage drop) within Specification?

YES

Faulty starter or Engine stuck

NO

Faulty harness between battery (-) terminal and chassis ground

Check the connecting condition of the starter.

Яндекс.Метрика