INSPECTION
OPERATION CHECK
INSPECT CIRCUITS FOR DAYTIME RUNNING LIGHT SYSTEM
1.

Disconnect the wire connector to DRL module(A) from the right side strut housing.

2.

Inspect the connector on wire harness side as shown.

Tester connection

Condition

Specified condition

1-Ground

Constant

Continuity

5-Ground

Head lamp switch OFF

No continuity

Head lamp switch ON

Continuity

6-Ground

Constant

Continuity

7-Ground

Constant

Battery voltage

9-Ground

Ignition switch ON or START

Battery voltage

Ignition switch ACC or LOCK

No voltage

11-Ground

Constant

Battery voltage

3-Ground

Engine Stop

No voltage

Engine Running

Battery voltage

If circuit is not as specified, refer to schematic diagram and inspect short or circuits.