Description

The purpose of the Inspection is to check TPS and TPS ajustment by using scaner(TPS output voltage). When throttle valve is entirely closed, If TPS output voltage is above the specified value, engine hesitation could occur.

Diagnostic Procedure
1.

IG "ON"

2.

Connect a scanner to Data Link Connector (DLC).

3.

Check current data.

A.

Specification :

Approx. 0.2~0.8V(0~0.5°) at idle

Approx. 4.3~4.8V(86°) at W.O.T

caution

This current data is nothing but an example at certain condition. Thus, the real current data and waveform could be different from this example.

4.

Is current data normal?

YES

TPS is OK.

NO

Check related harness or Replace the sensor.