When main relay is not operated although IG KEY "ON" signal circuit and main relay circuit are normal. Inspect the ECM ground.
IG KEY "OFF" , ENGINE "OFF"
Disconnect ECM connector.
Measure resistance between ECM connector (C330-2) terminal "2" ("4", "6") and chassis ground.
"ECM Connector Inspection" of "Details Inspection(Equipment Setting)" reference
Specification : Below 0.2 Ω
Case 1 : In case that all ECM grounds are normal.
Replace ECM when Main relay is not operated although IG KEY "ON" signal circuit, main relay circuit and ground circuit are normal.
Case 2 : In case that there is discontinuity or high resistance between ECM connector (C330-2) terminal "2" ( "4", "6") and chassis ground G39.
Repair open in ground circuit.
Repair chassis ground (G39).