Component Inspection
1.

Measure resistance between terminals 3 and 4 of the sensor connector(Component side)

a.

Specification

Temp.(℃)

Temp.(℉)

Front HO2S Heater Resistance(Ω)

Temp.(℃)

Temp.(℉)

Front HO2S Heater Resistance(Ω)

20

68

9.2

400

752

17.7

100

212

10.7

500

932

19.2

200

392

13.1

600

1,112

20.7

300

572

14.6

700

1,292

22.5

2.

Is HO2S heater resistance display near the specified value?

YES

▶ Check for poor connection between PCM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification of Vehicle Repair" procedure.

NO

▶ Check HO2S for contamination, deterioration, or damage. Substitute with a known-good HO2S and check for proper operation. If the problem is corrected, replace HO2S and then go to "Verification of Vehicle Repair" procedure.