Ignition "OFF".
Disconnect ICA valve connector.
Measure resistance between terminals 1 and 2 of the valve connector(Component side).
Specification
Temp.(℃) | Temp.(℉) | ICA Coil #1 (OPEN)(Ω) | Temp.(℃) | Temp.(℉) | ICA Coil #1 (OPEN)(Ω) |
-20 | -4 | 9.2 ~ 10.8 | 40 | 104 | 12.0 ~ 13.6 |
-10 | 14 | 9.7 ~ 11.3 | 50 | 122 | 12.4 ~ 14.0 |
0 | 32 | 10.2 ~ 11.8 | 60 | 140 | 12.9 ~ 14.5 |
10 | 50 | 10.6 ~ 12.2 | 70 | 158 | 13.4 ~ 15.0 |
20 | 68 | 11.1 ~ 12.7 | 80 | 176 | 13.8 ~ 15.4 |
30 | 86 | 11.5 ~ 13.1 | 100 | 212 | 14.7 ~ 16.3 |
Is resistance within the specification?
YES
▶ Go to next step as below.
NO
▶ Check ICA for contamination, deterioration, or damage. Substitute with a known-good ICA and check for proper operation. If the problem is corrected, replace ICA and then go to "Verification of Vehicle Repair" procedure.