The CVVT (Continuously Variable Valve Timing) system built on the camshaft helps the engine decrease the exhaust gas and increase engine power and fuel economy by changing the valve open/close timing of the intake camshaft continuously. The intake valve control solenoid, the main control part of the CVVT, changes the direction of the oil path through the CVVT by the duty control of the PCM and changes the open and close timing of the intake and exhaust valves.
PCM sets DTC P0076 if the PCM detects that the intake valve control solenoid control circuit is short to ground.
Item | Detecting Condition | Possible Cause |
DTC Strategy | ● Electrical check | ● Short to ground in control circuit ● Contact resistance in connectors ● Faulty Intake Valve Control Solenoid |
Enable Conditions | ● 100mS after ignition key ON ● 10 < Battery voltage <16 | |
Threshold Value | ● Short to ground | |
Diagnostic Time | ● 2 seconds. | |
Fail-Safe | ● No intake valve control solenoid activity |
Intake valve control solenoid | Normal Parameter |
Insulation Resistance (Ω) | above 50 ㏁ |
Temp.(℃) | Temp.(℉) | Resistance(Ω) | Temp.(℃) | Temp.(℉) | Resistance(Ω) |
0 | 32 | 6.2 ~ 7.4 | 60 | 140 | 8.0 ~ 9.2 |
10 | 50 | 6.5 ~ 7.7 | 70 | 158 | 8.3 ~ 9.5 |
20 | 68 | 6.8 ~ 8.0 | 80 | 176 | 8.6 ~ 9.8 |
30 | 86 | 7.1 ~ 8.3 | 90 | 194 | 8.9 ~ 10.1 |
40 | 104 | 7.4 ~ 8.6 | 100 | 212 | 9.2 ~ 10.4 |
50 | 122 | 7.7 ~ 8.9 |