Component Inspection
1.

Warm up the engine to normal operating temperature and check that HO2S signal is active.

2.

Install Scantool and monitor the "RR OXYGEN SNSR-B1" parameter on the Scantool data list.

Test Condition : Engine "ON" & In Idle("Closed Loop")condition

Specification : Above 0.6V

3.

Is "RR OXYGEN SNSR-B1" sensor data within the specification?

YES

▶ Check for poor connection between ECM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification of Vehicle Repair" procedure

NO

▶ Check HO2S for contamination, deterioration, or damage. Substitute with a known-good HO2S and check for proper operation. If the problem is corrected, replace HO2S and then go to "Verification of Vehicle Repair" procedure