System Inspection
1.

Igintion "ON" & Engine "OFF"

2.

Check Immobilizer indicator lamp.

caution

1. Normal Condition : After the IG ON, the Immobilizer lamp will be turned ON for 30 seconds then, goes off if the immobilizer system is O.K.

2. Malfunction on Immobilizer system : The immobilizer lamp will be blinking for 5 tiems then goes off.

3.

Is the immobilizer lamp operating correctly ?

YES

a.

Fault is intermittent caused by poor contact in the lamp’s and/or ECM’s connector or was repaired and ECM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corosion,contamination, deterioration, or damage. Repair or replace as necessary and then go to " Verification of Vehicle Repair" procedure.

NO

a.

Go to " Component Inspection" procedure.