Component Inspection
Check Humidity Sensor
1.

Engine "ON"

2.

Connect Humidity Sensor.

3.

Measure Frequency between terminal "3" and "5" of Humidity sensor

a.

Specification : Refer the specifications in fig3)

4.

Is the measured frequency within specifications in (fig5)? (tolerance limits ±5%)

※Check if frequency value is inversely proportional to humidity while increasing humidity.

YES

a.

Check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

NO

a.

Substitute with a known-good Humidity sensor and check for proper operation. If the problem is corrected, replace Humidity sensor and then go to "Verification of Vehicle Repair" procedure.