Variable Geometry Turbo-charger (VGT) is used to charge additional air into combustion chamber for improvement of combustion efficiency.
ECM controls the VGT with controlling duty of the VGT control solenoid valve according to engine load.
Items | Specification |
Coil Resistance (Ω) | 14.7 ~ 16.1Ω [20℃(68℉)] |
Turn ignition switch OFF.
Disconnect the VGT control solenoid valve connector.
Measure resistance between terminal 1 and 2 of the valve.
Specification: Refer to "SPECIFICATION".