INSPECTION
1.

Remove the fuse box cover.

2.

Remove the starter relay(A).

3.

Inspect the relay continuity.

A.

Using an ohmmeter, check that there is continuity between terminals 2 and 4.

If there is no continuity, replace the relay.

B.

Check that there is no continuity between terminals 1 and 5.

If there is continuity, replace the relay.

4.

Inspect the relay operation.

A.

Apply battery positive voltage across terminals 2 and 4.

B.

Using an ohmmeter, check that there is continuity between terminals 1 and 5.

If there is no continuity, replace the relay.

5.

Install the starter relay.

6.

Install the fuse box cover.